Office buildings

BMS for office buildings

In office buildings, providing an optimum work environment is besides the efficient use of resources of utmost importance. Only if the employee feels comfortable, which means the lighting conditions, room climate and the quality of the air is good, excellent work can be performed over a longer period. Not to loose sight of an optimum allocation of the available resources, there are plenty of possibilities:

Single room control

Several rooms of the building can be controlled separately. For example the heating of a room is in comfort mode only if the room is occupied. Also the rejected heat of technical devices or a higher amount of people in the room have to be considered.

Constant light control

The illumination intensity is constant through redemption or adding of artificial light depending on the share of natural light. Unnecessary artificial light and the arising costs are avoided. Too much artificial light might also effect the well-being of employees and lead to concentration disability, headache and exhaustion. Also an intelligent shading of the building considering the sun path, current weather situation and the shadow of the buildings nearby can have a positive effect.

Control as needed

Time circuit diagrams can avoid unnecessary waste of energy. In most cases it is sufficient to run in economy mode during the holiday or at night. Also conference rooms can be controlled according to the occupation of the room.

Presents detector for floors, toilets and before entry/exit

When a person steps into the determined area, the light turns on. Automatically turning off after a certain period can help to save resources. This is reasonable in rooms which are used at certain times or for short periods.

Including window contacts into the heating control

If a window is open, the heating power decreases. This can be supported by using a hysteresis. It avoids a permanent switching on and off of the heating, by not turning on the heating until a falling below a minimum value. The cycle of operation gets longer and can be used more reasonable.

Energy reporting

Even if the different measures for reduction of the energy consumptions are already realized, the analysis of the energy consumption can help to identify potentials for saving energy. By defining hierarchically organized cost center structure, the main energy consumers within the company might be detected. The evaluation of the consumption values with charts or tables over certain periods shows a longterm development.

Besides the complex requirements mentioned above, existing systems have to be integrated in the building automation system sometimes. Thereby, building automation systems with open interfaces to the common systems might help. For example information from web cams or access control systems can be integrated as well.

Lighting

HVAC

Shading

Trends/reports

Alarm management

Hotelmanagement

Door locking systems

Security

KNX

Sky Office

Croatia

NETx BMS Server, NETx Voyager, NETx Shutter Control
Data points: 35,000
Devices: 3,000
Trades: lighting, HVAC, supervision of LV cubicles, shading
System integrator: MC2 Ltd.

Sky Office is a business building in Zagreb, consisting of two towers with 22 floors and a four floor underground garage. With approximately 72,000 m² and a height of 81 m Sky Office is Croatia´s first object of this size on which a concept of surface heating and cooling, ventilation and humidity control is applied.

The system for lighting and shutter control is KNX. The integrator used NETx BMS Server for central management, NETx Voyager for visualisation as well as NETx Shutter Control. NETx Shutter Control is system based on meteorological data, the position of the sun, time, geographical location and information about the physics of the building and its environment. NETx Shutter Control uses all this data to control shutters and blinds. A 3D model of the building and its surroundings simulates the influence of the sun on each element for every day of the year to ensure perfect shading.

7 City Rd
Auckland, New Zealand
SmartBT
Frankfurter Welle
Frankfurt, Germany
EAB Rhein/Main
ZVK Wiesbaden
Wiesbaden, Germany
Hross & Partner GmbH
Federation Tower (VTB Headquarters)
Moscow, Russia
Ecoprog Ltd.
Samsung Headquarters
Seoul, South Korea
M-Nextec Inc.
Abu Dhabi National Oil Company (ADNOC) Headquarters
Abu Dhabi, UAE
ABB Industries Dubai
Oskar von Miller Forum
Munich, Germany
Hross & Partner GmbH
Sheikh Khalifa Energy Complex
Abu Dhabi, UAE
Atkins/IBA/DMJM
Federation of Korean Industries
Seoul, South Korea
M-Nex tec Inc.
Alizz Islamic Bank
Oman
CUBE LLC
Bertelsmann AG
Germany
Bertelsmann TGM/Elektrotechnik Corporate Center
WKO Linz
Linz, Austria
EQOS-ENERGIE Österreich GmbH
Town hall Linz
Linz, Austria
EQOS-ENERGIE Österreich GmbH
Etisalat T&A
Abu Dhabi, UAE
Cansult
Al Ain Diwan Building
Al Ain, UAE
KEO
ANZ Tower
Sydney, Australia
mySmartCTI
Turkish Contractors Association HQ
Turkey
Emes Electromechanical Ind&Trd.Co Ltd.
Petroleum Institute
Abu Dhabi, UAE
Hill International
National Bank of Abu Dhabi
Abu Dhabi, UAE
APG
Etisalat Building
Abu Dhabi, UAE
Shankland Cox