Office buildings

BMS for office buildings

In office buildings, providing an optimum work environment is besides the efficient use of resources of utmost importance. Only if the employee feels comfortable, which means the lighting conditions, room climate and the quality of the air is good, excellent work can be performed over a longer period. Not to loose sight of an optimum allocation of the available resources, there are plenty of possibilities:

Single room control

Several rooms of the building can be controlled separately. For example the heating of a room is in comfort mode only if the room is occupied. Also the rejected heat of technical devices or a higher amount of people in the room have to be considered.

Constant light control

The illumination intensity is constant through redemption or adding of artificial light depending on the share of natural light. Unnecessary artificial light and the arising costs are avoided. Too much artificial light might also effect the well-being of employees and lead to concentration disability, headache and exhaustion. Also an intelligent shading of the building considering the sun path, current weather situation and the shadow of the buildings nearby can have a positive effect.

Control as needed

Time circuit diagrams can avoid unnecessary waste of energy. In most cases it is sufficient to run in economy mode during the holiday or at night. Also conference rooms can be controlled according to the occupation of the room.

Presents detector for floors, toilets and before entry/exit

When a person steps into the determined area, the light turns on. Automatically turning off after a certain period can help to save resources. This is reasonable in rooms which are used at certain times or for short periods.

Including window contacts into the heating control

If a window is open, the heating power decreases. This can be supported by using a hysteresis. It avoids a permanent switching on and off of the heating, by not turning on the heating until a falling below a minimum value. The cycle of operation gets longer and can be used more reasonable.

Energy reporting

Even if the different measures for reduction of the energy consumptions are already realized, the analysis of the energy consumption can help to identify potentials for saving energy. By defining hierarchically organized cost center structure, the main energy consumers within the company might be detected. The evaluation of the consumption values with charts or tables over certain periods shows a longterm development.

Besides the complex requirements mentioned above, existing systems have to be integrated in the building automation system sometimes. Thereby, building automation systems with open interfaces to the common systems might help. For example information from web cams or access control systems can be integrated as well.

Lighting

HVAC

Shading

Trends/reports

Alarm management

Hotelmanagement

Door locking systems

Security

KNX

GAMA Headquarters

Turkey

NETx Voyager Server, NETx Voyager
Trades: lighting, HVAC, technical monitoring, energy management, access control
System integrator: Emes Elektromechanical Ind & Trd. Co Ltd

GAMA is a large concern from Turkey, specialized in industrial (e.g. power stations, pipelines, bridges) and civil (e.g. hospitals, hotels, housing complexes) projects. The building complex was built as „Green Building“ and has already won an environment award called “LEED EB GOLD“ as well as the KNX Award 2014 in the category „Energy Efficiency“.

 

NETx BMS Server is used for

  • OPC communication
  • HVAC control over BACnet/IP
  • Integration of the fire detection system over BACnet/IP
  • Integration of hazard and gas identification system over OPC
  • Integration CCTV over TCP

 

The integrator EMES Elektromechanical Ind & Trd. Co LTD. could realize remarkable savings in energy and water consumption through intelligent planning and implementation. The lighting is controlled automatically. Scene and brightness controller make sure that the lighting level is consistent. Presence and motion detectors are used for economical light on the parking space, at toilets and floors. During the night, a timer activates lighting scenes for security reasons. Visualizations are used for resolving technical problems and, if necessary, forwarding the data to mobile devices. To optimize the energy consumption, the consumption values of energy, water and gas meters are collected and analyzed. Furthermore, interfaces to CCTV, access and gate control are integrated in the building automation system. They can be controlled automatically.

7 City Rd
Auckland, New Zealand
SmartBT
Frankfurter Welle
Frankfurt, Germany
EAB Rhein/Main
ZVK Wiesbaden
Wiesbaden, Germany
Hross & Partner GmbH
Federation Tower (VTB Headquarters)
Moscow, Russia
Ecoprog Ltd.
Samsung Headquarters
Seoul, South Korea
M-Nextec Inc.
Abu Dhabi National Oil Company (ADNOC) Headquarters
Abu Dhabi, UAE
ABB Industries Dubai
Oskar von Miller Forum
Munich, Germany
Hross & Partner GmbH
Sheikh Khalifa Energy Complex
Abu Dhabi, UAE
Atkins/IBA/DMJM
Federation of Korean Industries
Seoul, South Korea
M-Nex tec Inc.
Alizz Islamic Bank
Oman
CUBE LLC
Bertelsmann AG
Germany
Bertelsmann TGM/Elektrotechnik Corporate Center
WKO Linz
Linz, Austria
EQOS-ENERGIE Österreich GmbH
Town hall Linz
Linz, Austria
EQOS-ENERGIE Österreich GmbH
Etisalat T&A
Abu Dhabi, UAE
Cansult
Al Ain Diwan Building
Al Ain, UAE
KEO
ANZ Tower
Sydney, Australia
mySmartCTI
Turkish Contractors Association HQ
Turkey
Emes Electromechanical Ind&Trd.Co Ltd.
Petroleum Institute
Abu Dhabi, UAE
Hill International
National Bank of Abu Dhabi
Abu Dhabi, UAE
APG
Etisalat Building
Abu Dhabi, UAE
Shankland Cox